Ecosora 12 kW Whole-Home Hybrid Inverter PLUS

The Ecosora GES48120M250-500XP-PLUS delivers 12 kW at 120/240 V split-phase and lists up to 24 kW of PV input.

Specifications

Model designationGES48120M250-500XP-PLUS
Rated split-phase output12 kW · 120/240 V AC
Rated battery voltage48 V class · 51.2 V DC (40–60 V DC)
Maximum PV input power24 kW
MPPT input current32 A + 32 A
Maximum PV charge current to battery250 A
Maximum battery discharge current270 A
UPS transfer10 ms typical
Parallel capacity listed1–6 units
Third-party mark shown in brochureETL / Intertek

Operating features

  • CT zero-export control, AC coupling and time-of-use (TOU) peak shaving.
  • Generator control with boost and SmartLoad input for microinverters.
  • AFCI, rapid shutdown (RSD) and insulation monitoring (ISO) protections listed in the brochure, plus touchscreen monitoring.
  • Up to six parallel units for a combined 72 kW as listed in the brochure.

Battery input

SpecificationBrochure value
Battery typeLi-ion or lead-acid
Maximum discharge current270 A DC
Maximum charge current250 A DC
Rated battery voltage and range51.2 V DC (40–60 V DC)
Wire size listed in brochure67 mm² / 00 AWG

PV input

SpecificationBrochure value
Number of PV circuits1 + 1
Recommended maximum PV power at module STC12,000 W + 12,000 W
Maximum PV input voltage500 V DC
PV array MPPT voltage range90–450 V DC
MPPT input current32 A DC + 32 A DC
Maximum PV charge current to battery250 A DC
Wire size listed in brochure5.2 mm² / 10 AWG

AC input

SpecificationBrochure value
Nominal input voltage120/120 V AC (L1/L2/N/PE)
Rated phase input power12,000 W
Input voltage range90–140 V AC / 90–140 V AC
Frequency50 Hz / 60 Hz
Bypass / inverter transfer time10 ms typical
Maximum rated phase input current200 A AC / 200 A AC
Maximum AC charge current to battery160 A DC

AC output

SpecificationBrochure value
Rated output12,000 W split-phase / 7,200 W single-phase (wiring terminal limit)
Peak power (brochure table)18,000 W split-phase / 18,000 W single-phase
Rated phase output current50 A AC / 50 A AC
Maximum bypass current2-pole, 63 A on L1 and 63 A on L2
Power factor1
Parallel connection (brochure table)1–6 units

Generator input

SpecificationBrochure value
Rated input voltage120 V AC (L1–N, L2–N) / 240 V AC (L1–L2)
Input phase voltage range90–140 V AC
Frequency range40 ± 0.3 Hz to 70 ± 0.3 Hz
Maximum charge current (AC, brochure row)160 A AC
Maximum bypass current2-pole, 63 A on L1 and 63 A on L2

Efficiency

SpecificationBrochure value
Maximum AC-mode efficiency>95%
Maximum inverter-mode efficiency>93%

General

SpecificationBrochure value
Protection classI
Overvoltage categoryDC OVC II / AC OVC III
Certification listedUL 1741
EMC classification listedFCC Part 15, Class B
Ingress protectionIP21
Operating temperature−10 to 55 °C, derating above 45 °C
Storage temperature−25 to 60 °C
Humidity5–95% (conformal coating)
Noise≤60 dB
Communications and controlUSB, RS-485 (Wi-Fi/GPRS), dry-contact control
Dimensions (L × W × D)785 × 485 × 160.8 mm
Weight35.8 kg

Product documentation

Source: Ecosora North America product brochure, July 26, 2026.

Use the GES48120M250-500XP-PLUS documentation when checking AC input and bypass limits or specifying a generator or AC-coupled solar system.