Ecosora 6.2 kW Split-Phase Hybrid Inverter
GES4862M120-500 · 9 kW PV input
View modelCompare Ecosora 120/240 V split-phase hybrid inverters from 6.2 to 12 kW for residential solar, battery storage and home backup.
Check each model’s documentation for the application, power rating and market variant.

GES4862M120-500 · 9 kW PV input
View model
GES4880M160-500P · 10 kW PV input
View model
GES48100M220-500P · 12 kW PV input
View model
GES48120M250-500XP · 24 kW PV input
View model
GES48120M250-500XP-PLUS · 24 kW PV input
View model| Model | Split-phase output | PV input | MPPT input current | Max. PV charge current |
|---|---|---|---|---|
| GES4862M120-500 | 6.2 kW | 9 kW | 27 A | 120 A |
| GES4880M160-500P | 8 kW | 10 kW | 18 A + 18 A | 160 A |
| GES48100M220-500P | 10 kW | 12 kW | 22 A + 22 A | 220 A |
| GES48120M250-500XP | 12 kW | 24 kW | 32 A + 32 A | 250 A |
| GES48120M250-500XP-PLUS | 12 kW | 24 kW | 32 A + 32 A | 250 A |
The compact 12 kW and whole-home PLUS both list 24 kW PV input. The brochure lists 60 A AC per leg as the compact model’s maximum rated AC phase input current and 200 A AC per leg for the PLUS. Both list a separate 63 A per-leg bypass limit.
Ecosora’s residential system overview shows solar, battery, grid and generator sources serving 120 V and 240 V loads. Refer to each model page for supported modes, nameplate limits and model-specific options.
Confirm L1–N, L2–N and L1–L2 voltage and frequency specifically in inverter mode. A unit can accept or pass 120/240 V AC from an upstream source while providing only 120 V from the battery. Manufacturer operating example.
For a 240 V load that must run during an outage, include its running and startup demand and the other loads on each leg.
| Specification group | What to verify |
|---|---|
| Battery input | Supported DC voltage range, maximum current and battery/BMS compatibility |
| PV input | MPPT range, maximum PV open-circuit voltage, and PV input limits if solar charging is built in |
| AC input and bypass | Supported supply, input current and transfer behavior |
| AC output | Voltage between legs in inverter mode, continuous and surge power, and limits per leg |
| Documentation | Exact model, regional variant, dimensions and applicable certifications |
Match the published DC operating range to the battery pack. If you are evaluating a 48 V system, compare the pack and inverter documentation together. Include the peak discharge needed for startup in the load list.
See the split-phase explanation for the difference between two 120 V circuits and split-phase inverter output.
Specify the battery system, required AC output and largest 240 V load.