Specifications
| Model designation | GES48120M250-500XP |
|---|
| Rated split-phase output | 12 kW · 120/240 V AC |
|---|
| Rated battery voltage | 48 V class · 51.2 V DC (40–60 V DC) |
|---|
| Maximum PV input power | 24 kW |
|---|
| MPPT input current | 32 A + 32 A |
|---|
| Maximum PV charge current to battery | 250 A |
|---|
| Maximum battery discharge current | 270 A |
|---|
| UPS transfer | 10 ms typical |
|---|
| Parallel capacity listed | 1–6 units |
|---|
| EPS output (brochure feature rating) | 150% for 5 seconds |
|---|
| Third-party mark shown in brochure | ETL / Intertek |
|---|
Operating features
- CT zero-export control and AC coupling with time-of-use (TOU) peak shaving.
- Up to six parallel units for a combined 72 kW as listed in the brochure.
- Generator control, battery-free PV/grid supply, battery activation from PV or the grid, and touchscreen operation.
AC output
| Specification | Brochure value |
|---|
| Rated output | 12,000 W split-phase / 7,200 W single-phase (wiring terminal limit) |
|---|
| Peak power (brochure table) | 18,000 W split-phase / 18,000 W single-phase |
|---|
| Rated phase output current | 50 A AC / 50 A AC |
|---|
| Maximum bypass current | 2-pole, 63 A on L1 and 63 A on L2 |
|---|
| Power factor | 1 |
|---|
| Parallel connection (brochure table) | 1–6 units |
|---|
Efficiency
| Specification | Brochure value |
|---|
| Maximum AC-mode efficiency | >95% |
|---|
| Maximum inverter-mode efficiency | >91% |
|---|
General
| Specification | Brochure value |
|---|
| Protection class | I |
|---|
| Overvoltage category | DC OVC II / AC OVC III |
|---|
| Certification listed | UL 1741 / CSA C22.2 No. 107.1 |
|---|
| EMC classification listed | FCC Part 15, Class B |
|---|
| Ingress protection | IP21 |
|---|
| Operating temperature | −10 to 55 °C, derating above 45 °C |
|---|
| Storage temperature | −25 to 60 °C |
|---|
| Humidity | 5–95% (conformal coating) |
|---|
| Noise | ≤60 dB |
|---|
| Communications and control | USB, RS-485 (Wi-Fi/GPRS), dry-contact control |
|---|
| Dimensions (L × W × D) | 620 × 450 × 132 mm |
|---|
| Weight | 23.8 kg |
|---|
Product documentation
Source: Ecosora North America product brochure, July 26, 2026.
Use the GES48120M250-500XP documentation when checking AC input current, enclosure dimensions and applicable approvals.
Prepare an RFQ
Include the exact model, installation market, largest loads and proposed battery bank to request a current datasheet and quote.